ECOCONDENS SOLID PLUS is a ready-to-connect heating unit in a single, compact and aesthetically designed casing. The unit consists of: the latest generation condensing boiler combined with a 107-litre storage tank made entirely of stainless steel, expansion vessels for domestic hot water and central heating as well as a modern boiler control system that enables a.o. remote operation via smartphone or tablet by an individual customer and remote monitoring of the boiler by service technician.

FREEPHONE: 0800 689 3538

Boiler Overview

  • energy class: A
  • Easily convertible from COMBI to LPG by simple settings change
  • heat exchanger made of stainless steel
  • wide range of modulation: from 11% to 100%
  • high efficiency circulation pump
  • stepless speed regulation fan (controlled electronically)
  • cylinder burner made of stainless steel – low level of NOx emission (6th class)
  • domestic hot water cylinder by 3-way valve (refers to system boilers)
  • complete protection system
  • optimization of boiler operation is possible due to application of:
  • outdoor temperature sensor
  • temperature regulator: ON/OFF, Open-Therm or 0-10V,
  • ROUND system for remote boiler control via smartphone,
  • EVOHOME system for remote control of up to 11 heating zones
  • ready-to-use multi-zone modules for controlling up to 3 SIM heating systems
  • boilers can also cooperate with:
    • heat pumps air/water
    • solar panels

Boiler SPECS

Thermal power (at temp. 80/60°C) 2,7-20,0 kW
Thermal power (at temp. 50/30°C) 3,0-22,0 kW
Heat load 2,8-20,4 kW
Seasonal space heating energy efficiency ηs 94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
97,6 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
107,9 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers – arithmetic mean of min and max)
20,0 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers – 30% of arithmetic mean)
6,0 kW
Efficiency η4 88,0 %
Efficiency η1 97,0 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40-80 °C
Reduced adjustable temperature 25-55 °C
Pump head at 0 flow 0,6 bar
Nominal boiler thermal power (at temperature 80/60°C) 2,7-25 kW
Nominal heat load 2,8-25,6 kW
Water pressure 0,1-6 bar
Minimal water flow 2,7 dm³/min
Domestic water flow at Δt=30K 12,4 dm³/min
Energy efficiency class of water heating A
Load profile L
Range of water temperature regulation 30-60 °C
Sound power level LWA 44 dB
Emission of nitrogen dioxide 21 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Max. amount of condensate (natural gas) 2 l/h
Expansion vessel capacity 8 dm³
Standby mode power consumption PSB 0,005 kW
Electricity consumption at full load elmax 0,05 kW
Electricity consumption at partial load elmax 0,02 kW
Type and supply voltage ~ 230 ±10%/ 50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 1869x520x490 mm
Weight 94 kg
Domestic water connection G1/2 inch
Heat exchanger material stainless steel
Coil power 30 kW
Cylinder position vertical
Cylinder capacity 107 dm³
Coil capacity 5 dm³
Thermal power (at temp. 80/60°C) 3,9-24,0 kW
Thermal power (at temp. 50/30°C) 4,3-26,5 kW
Heat load 4,0-24,6 kW
Seasonal space heating energy efficiency ηs 94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
108,7 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers – arithmetic mean of min and max)
24,0 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers – 30% of arithmetic mean)
7,2 kW
Efficiency η4 87,9 %
Efficiency η1 96,9 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40-80 °C
Reduced adjustable temperature 25-55 °C
Pump head at 0 flow 0,6 bar
Nominal boiler thermal power (at temperature 80/60°C) 3,9-30,0 kW
Nominal heat load 4,0-30,7 kW
Water pressure 0,1-6 bar
Minimal water flow 2,7 dm³/min
Domestic water flow at Δt=30K 13,1 dm³/min
Energy efficiency class of water heating A
Load profile XL
Range of water temperature regulation 30-60 °C
Sound power level LWA 46 dB
Emission of nitrogen dioxide 24 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Max. amount of condensate (natural gas) 2,8 l/h
Expansion vessel capacity 8 dm³
Standby mode power consumption PSB 0,005 kW
Electricity consumption at full load elmax 0,05 kW
Electricity consumption at partial load elmax 0,02 kW
Type and supply voltage ~ 230 ±10%/ 50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 1869x520x490 mm
Weight 96 kg
Domestic water connection G1/2 inch
Heat exchanger material stainless steel
Coil power 30 kW
Cylinder position vertical
Cylinder capacity 107 dm³
Coil capacity 5 dm³
Thermal power (at temp. 80/60°C) 4,1-34,7 kW
Thermal power (at temp. 50/30°C) 4,5-38,2 kW
Heat load 4,2-35,6 kW
Seasonal space heating energy efficiency ηs 94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
109,0 %
Seasonal space heating energy efficiency class A
Useful heat output at rated thermal power P4 (for modulated
boilers – arithmetic mean of min and max)
34,6 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers – 30% of arithmetic mean)
10,4 kW
Efficiency η4 87,8 %
Efficiency η1 96,5 %
Max water pressure 3 bar
Max CH temperature 95 °C
Standard adjustable temperature 40-80 °C
Reduced adjustable temperature 25-55 °C
Pump head at 0 flow 0,7 bar
Nominal boiler thermal power (at temperature 80/60°C) 4,1-30,0 kW
Nominal heat load 4,2-30,7 kW
Water pressure 0,1-6 bar
Minimal water flow 2,7 dm³/min
Domestic water flow at Δt=30K 13,1 dm³/min
Energy efficiency class of water heating A
Load profile XL
Range of water temperature regulation 30-60 °C
Sound power level LWA 48 dB
Emission of nitrogen dioxide 29 mg/kWh
Emission class of nitrogen dioxide (NOx) 6
Max. amount of condensate (natural gas) 3,5 l/h
Expansion vessel capacity 8 dm³
Standby mode power consumption PSB 0,005 kW
Electricity consumption at full load elmax 0,05 kW
Electricity consumption at partial load elmax 0,02 kW
Type and supply voltage ~ 230 ±10%/ 50Hz V
Protection degree IPX4D
Heating water and gas connection G3/4 inch
Dimensions 1869x520x490 mm
Weight 98 kg
Domestic water connection G1/2 inch
Heat exchanger material stainless steel
Coil power 30 kW
Cylinder position vertical
Cylinder capacity 107 dm³
Coil capacity 5 dm³

 