Ecocondens Solid Plus

 

ECOCONDENS SOLID PLUS is a ready-to-connect heating unit in a single, compact and aesthetically designed casing. The unit consists of: the latest generation condensing boiler combined with a 107-litre storage tank made entirely of stainless steel, expansion vessels for domestic hot water and central heating as well as a modern boiler control system that enables a.o. remote operation via smartphone or tablet by an individual customer and remote monitoring of the boiler by service technician.

CALL: 01282 772 570

Boiler Overview

  • energy class: A
  • Easily convertible from COMBI to LPG by simple settings change
  • heat exchanger made of stainless steel
  • wide range of modulation: from 11% to 100%
  • high efficiency circulation pump
  • stepless speed regulation fan (controlled electronically)
  • cylinder burner made of stainless steel – low level of NOx emission (6th class)
  • domestic hot water cylinder by 3-way valve (refers to system boilers)
  • complete protection system
  • optimization of boiler operation is possible due to application of:
  • outdoor temperature sensor
  • temperature regulator: ON/OFF, Open-Therm or 0-10V,
  • ROUND system for remote boiler control via smartphone,
  • EVOHOME system for remote control of up to 11 heating zones
  • ready-to-use multi-zone modules for controlling up to 3 SIM heating systems
  • boilers can also cooperate with:
    • heat pumps air/water
    • solar panels

Boiler SPECS

Thermal power (at temp. 80/60°C)2,7-20,0 kW
Thermal power (at temp. 50/30°C)3,0-22,0 kW
Heat load2,8-20,4 kW
Seasonal space heating energy efficiency ηs94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
97,6 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
107,9 %
Seasonal space heating energy efficiency classA
Useful heat output at rated thermal power P4 (for modulated
boilers – arithmetic mean of min and max)
20,0 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers – 30% of arithmetic mean)
6,0 kW
Efficiency η488,0 %
Efficiency η197,0 %
Max water pressure3 bar
Max CH temperature95 °C
Standard adjustable temperature40-80 °C
Reduced adjustable temperature25-55 °C
Pump head at 0 flow0,6 bar
Nominal boiler thermal power (at temperature 80/60°C)2,7-25 kW
Nominal heat load2,8-25,6 kW
Water pressure0,1-6 bar
Minimal water flow2,7 dm³/min
Domestic water flow at Δt=30K12,4 dm³/min
Energy efficiency class of water heatingA
Load profileL
Range of water temperature regulation30-60 °C
Sound power level LWA44 dB
Emission of nitrogen dioxide21 mg/kWh
Emission class of nitrogen dioxide (NOx)6
Max. amount of condensate (natural gas)2 l/h
Expansion vessel capacity8 dm³
Standby mode power consumption PSB0,005 kW
Electricity consumption at full load elmax0,05 kW
Electricity consumption at partial load elmax0,02 kW
Type and supply voltage~ 230 ±10%/ 50Hz V
Protection degreeIPX4D
Heating water and gas connectionG3/4 inch
Dimensions1869x520x490 mm
Weight94 kg
Domestic water connectionG1/2 inch
Heat exchanger materialstainless steel
Coil power30 kW
Cylinder positionvertical
Cylinder capacity107 dm³
Coil capacity5 dm³
Thermal power (at temp. 80/60°C)3,9-24,0 kW
Thermal power (at temp. 50/30°C)4,3-26,5 kW
Heat load4,0-24,6 kW
Seasonal space heating energy efficiency ηs94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
108,7 %
Seasonal space heating energy efficiency classA
Useful heat output at rated thermal power P4 (for modulated
boilers – arithmetic mean of min and max)
24,0 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers – 30% of arithmetic mean)
7,2 kW
Efficiency η487,9 %
Efficiency η196,9 %
Max water pressure3 bar
Max CH temperature95 °C
Standard adjustable temperature40-80 °C
Reduced adjustable temperature25-55 °C
Pump head at 0 flow0,6 bar
Nominal boiler thermal power (at temperature 80/60°C)3,9-30,0 kW
Nominal heat load4,0-30,7 kW
Water pressure0,1-6 bar
Minimal water flow2,7 dm³/min
Domestic water flow at Δt=30K13,1 dm³/min
Energy efficiency class of water heatingA
Load profileXL
Range of water temperature regulation30-60 °C
Sound power level LWA46 dB
Emission of nitrogen dioxide24 mg/kWh
Emission class of nitrogen dioxide (NOx)6
Max. amount of condensate (natural gas)2,8 l/h
Expansion vessel capacity8 dm³
Standby mode power consumption PSB0,005 kW
Electricity consumption at full load elmax0,05 kW
Electricity consumption at partial load elmax0,02 kW
Type and supply voltage~ 230 ±10%/ 50Hz V
Protection degreeIPX4D
Heating water and gas connectionG3/4 inch
Dimensions1869x520x490 mm
Weight96 kg
Domestic water connectionG1/2 inch
Heat exchanger materialstainless steel
Coil power30 kW
Cylinder positionvertical
Cylinder capacity107 dm³
Coil capacity5 dm³
Thermal power (at temp. 80/60°C)4,1-34,7 kW
Thermal power (at temp. 50/30°C)4,5-38,2 kW
Heat load4,2-35,6 kW
Seasonal space heating energy efficiency ηs94 %
Efficiency of the boiler at nominal load and average
boiler water temperature of 70°C
98 %
Efficiency of the boiler at partial load
and return water temperature of 30°C
109,0 %
Seasonal space heating energy efficiency classA
Useful heat output at rated thermal power P4 (for modulated
boilers – arithmetic mean of min and max)
34,6 kW
Useful heat output at 30% of rated power P1 (for modulated
boilers – 30% of arithmetic mean)
10,4 kW
Efficiency η487,8 %
Efficiency η196,5 %
Max water pressure3 bar
Max CH temperature95 °C
Standard adjustable temperature40-80 °C
Reduced adjustable temperature25-55 °C
Pump head at 0 flow0,7 bar
Nominal boiler thermal power (at temperature 80/60°C)4,1-30,0 kW
Nominal heat load4,2-30,7 kW
Water pressure0,1-6 bar
Minimal water flow2,7 dm³/min
Domestic water flow at Δt=30K13,1 dm³/min
Energy efficiency class of water heatingA
Load profileXL
Range of water temperature regulation30-60 °C
Sound power level LWA48 dB
Emission of nitrogen dioxide29 mg/kWh
Emission class of nitrogen dioxide (NOx)6
Max. amount of condensate (natural gas)3,5 l/h
Expansion vessel capacity8 dm³
Standby mode power consumption PSB0,005 kW
Electricity consumption at full load elmax0,05 kW
Electricity consumption at partial load elmax0,02 kW
Type and supply voltage~ 230 ±10%/ 50Hz V
Protection degreeIPX4D
Heating water and gas connectionG3/4 inch
Dimensions1869x520x490 mm
Weight98 kg
Domestic water connectionG1/2 inch
Heat exchanger materialstainless steel
Coil power30 kW
Cylinder positionvertical
Cylinder capacity107 dm³
Coil capacity5 dm³

 

The mobile App Comfort Version and the mobile app Service Version diagram show just how easy it is for you to connect to and control your boiler and heating system, monitor the operation of the boiler against the service parameters and diagnose any error codes.

Get it Now!

Your Ecocondens Solid Plus boiler is just a couple of clicks away!